Advances in Industrial Humanoid Robots

Newsletter header - volume 13 issue 2
In this issue:
• Latest advances in industrial humanoid robots
• Sensor Tip: Advantages of programmable linear sensors
• Application: Tractor trailer wheel positioning
• and more.
To view newsletter in your browser click here.

Featured video: https://www.youtube.com/watch?v=rrUHZKlrxms


Latest Humanoid Industrial Robot Advances
Stock photo. Video shows latest humanoid robot advances.
Tech News
Latest Humanoid Industrial Robot Advances
Digit’s first day on the job
Stock photo. Video shows Agility Robotics' humanoid robot Digit's
first day on the job.
Two leaders in industrial humanoid robots have made substantial advances recently. Agility Robotics had the first contracted commercial use of humanoid robots with their customer GXO Logistics. Their robot, called Digit, was deployed in Flowery Branch, Georgia. As of November 20 last year, Digit moved over 100,000 totes at that location. Agility continues to advance their robotic offerings.1,2
The second leader is a MIT spinoff called Boston Dynamics. One of the things they discovered, as they developed robots in general, was that to be useful in a world with things like stairs, doors and other obstacles, they had to have arms and legs. In other words a humanoid robot was needed for any task beyond where a fixed robotic arm-type of robot could be used.3

They have been bought and sold by Google and a Japanese investment company before being acquired by Hyundai. One main thing that was holding them back from producing a commercially viable product was creating an actuator that could stand up to constant tough use and be accurate and reliable in an industrial environment. Hyundai had actuators in production for years and used in their cars for steering, so they had a usable technology baseline to adapt their designs for use in robotics.3

This year they have culminated 10 years or R & D with the release of their robot Atlas. This humanoid robot is 6.2 ft tall and weighs 198 lbs with a 7.5 ft reach from floor to robotic finger tips, raised overhead. Atlas can carry a maximum of 66 to 110 lbs – depending on duration. Designed to work in areas with people, Atlas has “human detection” and stops when a person comes within a certain distance from it. Atlas is programmed to replace its own 4 hr battery, so it can operate continuously. Boston Dynamics' CEO announced in January, that mass production of Atlas is underway.4

Both of these robotics companies demonstrated these robots at CES this year and with the integration of A.I. they are greatly expanding humanoid robot deployment in factories and other commercial applications in the very near future.
Sources:
1.
https://www.agilityrobotics.com/content/digit-moves-over-100k-totes
2. https://www.youtube.com/watch?v=AJpTpUqjgrY
3. https://www.youtube.com/watch?v=rrUHZKlrxms
4. https://www.youtube.com/watch?v=ll784fIsQew
5. https://www.youtube.com/watch?v=TlPYlsuR1DE
Sensor Tip
When a Programmable Linear Sensor Provides Real Advantages in Applications

• Preventing incorrect or undefined states at either end of a linear sensor, especially for actuator or valve applications and any robotics or mobile application
• Control loop applications
• Applications that benefit from multi-point sensor calibration
• High accuracy applications

Additionally, this issue's Sensor Tip section seeks to answer the following questions regarding end-user programming of non-contacting position sensors with analog outputs for general machine automation purposes:

• When does programming after assembly of your product or in the field make sense?
• Is it quick & easy?

Some applications have a moving component that needs to have a start point that is non-zero. For these applications, an offset can be programmed into a programmable position sensor. Many users buy a linear sensor that has a longer mechanical stroke length than their application needs, so they do not run the position sensor all the way to the end-stop. For these situations an end point can be programmed in.

An example would be an application that requires linear movement of 50 mm and needs a 5 mm offset from the zero point. A position sensor with a 50 mm electrical stroke length can be specified. The 5 mm offset can be programmed in and an end point of 45 mm can be set.

We’ll use Novotechnik’s TP1 Series of programmable linear position sensors as a programming example. The programming process is referred to as Teach-In. Before defining an offset and end-point with a TP1 sensor, first have a voltmeter on hand to monitor the sensor output. Teach-In should not be activated during operation of the application machine the sensor is or will be connected to.

Position Programming

This section describes the procedure for programming zero point (offset) and end point for an analog output TP1 sensor. Note: if the Teach-In procedure is not finalized (saved to the sensor) by the user, it will end by itself after 180 seconds and and the settings will not be saved.

The TP1 sensors with analog output (either 0 to 10 VDC, 0 to 20 or 4 to 20 mA— both DC) have the following connections. Note: DIAG and PROG should only be connected when programming the sensor.

Table
Drawing 1
Position Sensor Programming Example TP1 Analog

Programming steps:

Figure 1


1) Activation of Teach-In Mode
Do not connect PROG and DIAG to each other before starting the Teach-In (programming) process. Place sensor’s position marker at the zero point on the sensor.

Begin Teach-In process:
Connect PROG to GND and within 0.5 sec also connect DIAG to GND
and leave both connected to GND for 3 to 6 seconds. Position Teach-In mode is now activated. Zero (offset) and end point can be set after an additional 1 second or more. Then remove PROG and DIAG from GND.

Figure 2
Teach-In programming setup, switching and timing

2) Setting Zero Point (Offset)
a) Move the sensor’s position marker to the offset position.
b) Connect PROG for 3 to 6 seconds to GND. Then remove PROG from GND.

Zero point (offset) is now set. Output voltage should now read minimum range value of 0 V or 0 mA or 4 mA DC— depending on output type.

Figure 3

Zero set point (offset) setup, switching and timing

3) Setting End Point (full scale)
a) Move position marker to desired full scale position(s) on the sensor.
b) Connect DIAG to GND for 3 to 6 seconds. Then remove DIAG from GND.

End point is now set.
Output voltage should now read maximum range value of 10 V or 20 mA DC— depending on output type.

Figure 5

End point setup, switching and timing

4) Finalize Teach-In Programming
First connect PROG to GND and within 0.5 seconds, also connect DIAG to GND and leave both connected to GND for at least 6 seconds.

Figure 4

Visualization of finalization procedure to store settings in the TP1 sensor

After the stated programming times as well as after completion of the Teach-In procedure, PROG and DIAG have to be disconnected from GND.

The programming sequence of zero and/or end-point can be made in any order and as often as needed.

A programming of only zero point (offset) or end point can be done as well.

For an inverted output with the slope ramping down instead of up as output (stroke amount) is increased, program an end point position that is smaller than the start point position.

5) If Factory Reset Is Needed (Master Reset)
Teach-In procedure must be completed before starting reset procedure.

First, connect PROG to GND
and within 0.5 seconds also connect DIAG to GND and leave both connected to GND for at least 6 seconds.

After the stated programming times, PROG and DIAG have to be disconnected from GND.

Figure6

Visualization of Factory Reset procedure

End Programming procedures

The above procedures show the programming can be reasonably quick and easy, though buying or building a simple hardware device made up of two SPST (single throw single pole switches can make the programming even easier by speeding up the connection and disconnection times compared to doing it by hand.
Application header
Wheel Positioning On Trailer for Oversized Loads
harvester
A tractor trailer manufacturer to monitor the position of each wheel on a customizable flatbed/step-deck semi-trailer. The wheels needed to be positioned independently for turning while transporting very large and long loads. Sections of trailer can be added to lengths that require many dozens of wheels. They selected the RFC 4800 Series of magnetic angle sensors for several reasons that aligned with their application. This sensor has linearity to < ±0.5 %, repeatability to < 0.1° and 12-bit resolution. This sensor features seven output options including current or voltage analog output, as well as CAN SAE J1939, SSI, IO-Link and incremental. View an application / demo video of this sensor family here.
Featured product - TM1