History, Overview and How to Apply the SAE J1939 Interface (continued)
How to Apply SAE J1939
Applying SAE J1939 involves understanding its structure, selecting the right hardware/software, and integrating the protocol into your embedded system, telematics device, or diagnostic tool. Below is a practical, step-by-step guide.
1. Understand Your Use Case
Identify what you want to achieve:
• Reading engine speed, temperatures, pressures • Logging diagnostic codes (DM1, DM2) • Controlling actuators (torque control, retarder, etc.) • Communicating with ECUs in heavy equipment
Your use case determines which PGNs/SPNs you must support.
2. Get the Required Documents
SAE J1939 is a family of standards. Common ones include:
• J1939-21: Data link layer • J1939-71: Vehicle application layer (PGNs and SPNs) • J1939-73: Diagnostics • J1939-81: Network management
These describe message formats, timing, and parameter definitions.
3. Choose the Hardware
You need:
• A CAN transceiver • A CAN controller or MCU with CAN built-in • Optional gateway or telematics device for logging
Common microcontrollers:
• STM32 (bxCAN, FDCAN) • Microchip PIC/dsPIC/AVR with CAN • NXP LPC/FlexCAN
For testing, USB-to-CAN tools help:
• Peak PCAN • Kvaser Leaf • Vector VN series
4. Implement or Use a J1939 Stack
You can either:
• Use an existing J1939 software stack • Develop your own
A minimal stack includes:
• CAN driver • 29-bit ID encoder/decoder • PGN and SPN management • Transport Protocol (BAM, RTS/CTS) • Address claiming • Diagnostics handler
5. Encode/Decode CAN IDs and PGNs
Every frame uses a 29-bit CAN identifier. You need to extract:
• Priority • PDU Format (PF) • PDU Specific (PS) • Source Address
Then derive the PGN:
PGN = (DP ⋅ 216 ) + (PF ⋅ 28 ) + PS
For PDU1 messages (PF < 240), PS is a destination address; PGN ends with 00.
6. Handling Multi-Packet Messages
Implement:
• BAM for broadcast messages • RTS/CTS for peer-to-peer transfers
This is needed for large messages such as DM messages and proprietary data.
7. Parse SPNs Inside PGNs
Each SPN has:
• Length in bits/bytes • Scaling/resolution • Offset • Valid range
Example: Engine Speed (SPN 190) Speed = 0.125 ⋅ raw
8. Implement Diagnostics
Support key diagnostic messages:
• DM1: Active faults • DM2: Previously active faults • DM3–DM7: Clearing faults, freeze frames • DTC decoding using SPN + FMI
This enables real-world fault monitoring.
9. Perform Testing
Verify:
• Timing and repetition rates of PGNs • Correct decoding/encoding of SPNs • Network management (address claim) • Handling bus load (typically 40–70% max load)
Use CAN analyzers for validation.
10. Integrate Into the System
Depending on the project:
• ECU firmware: embed the stack into your application • Telematics: log PGNs and send to server • Diagnostics: create a scan tool interface • Gateway: translate between J1939 and other protocols
Physical Connections of a J1939 Interface Sensor to a J1939 Network
Below is a clear, practical guide for wiring any sensor with a J1939 interface into a vehicle or machine J1939 CAN bus.
1. Required Physical Signals
A J1939-compliant sensor typically has 4 or 5 wires:
• CAN-High (CAN-H) • CAN-Low (CAN-L) • Power Supply (+12 V or +24 V, depending on system) • Ground (GND)• Optional: Shield / Drain Wire (SHLD)
These connect directly to the vehicle’s J1939 CAN backbone.
2. Standard Wiring Connections
Connect as follows:
• Sensor CAN-H → Vehicle CAN-H • Sensor CAN-L → Vehicle CAN-L • Sensor Power Input → Vehicle +12 V or +24 V • Sensor Ground → Vehicle Ground • Sensor Shield → Vehicle shield or chassis ground (if provided)
Ensure:
• Ground is common with the vehicle • CAN wires are twisted pair
3. Termination Rules (Very Important)
The J1939 backbone requires exactly two 120 Ω terminators:
• One at each physical end of the bus • Sensors should NOT have termination unless they are at the end of the bus
If the sensor includes a termination resistor option:
• Disable it unless it is physically at the bus end
4. Stub Length Requirements
J1939 uses a backbone + short stubs.
• Maximum stub length: ≤ 1 meter • Avoid long drops to the sensor • Use proper twisted-pair cabling
5. Power Requirements
Typical:
• 9–32 V DC wide-range input for heavy-duty systems • Sensor ground must match vehicle ground
Include:
• Reverse-polarity protection (often built into sensor) • Proper fusing on the power feed
6. Shielding and EMI Considerations
If your cable has shielding:
• Connect shield to vehicle ground at one end only • Do not ground both ends to avoid ground loops
This improves noise immunity for long cable runs.
7. J1939 Connector Types (Common)
Depending on the vehicle or equipment, you will encounter:
• Deutsch 9-pin (J1939 Type I or Type II) • Deutsch 6-pin (older) • Custom OEM harness connectors
Pins typically include:
• CAN-H • CAN-L • Battery + • Ground
8. What Happens After Physical Connection
Once wired:
• The sensor announces its Source Address using address-claiming • It begins broadcasting PGNs (Position, Angle, Pressure, etc.) • Other ECUs or controllers listen automatically
No extra configuration is needed unless the manufacturer requires SA or baud-rate setup.
9. Quick Checklist
• Twisted pair CAN wiring used • CAN-H and CAN-L polarity correct • Power matches 12/24 V system • Only two terminators on the bus • Stub length < 1 meter • Shield grounded on one end
Connecting a Magnetic Multi-Turn Rotary Sensor to a J1939 Network
Below is a clear, practical guide to integrating a magnetic multi-turn rotary sensor (typically SSI, SPI, analog, or CAN-based) into a J1939 network.
1. Identify Your Sensor Type
Magnetic multi-turn rotary sensors normally come in three categories:
A. Native J1939-Output Sensor
Best case — The sensor already supports SAE J1939 and outputs PGNs directly.
B. CAN Sensor (Non-J1939)
Outputs raw CAN frames but not in J1939 format → Requires a gateway or custom firmware to convert to PGNs.
C. Non-CAN Sensor
SSI, SPI, I²C, analog voltage, PWM → Requires a microcontroller interface to read the sensor and publish J1939 messages.
2. Choose the Integration Method
Case A: Sensor with Native J1939 Support
You only need to:
• Connect CAN-High, CAN-Low, +V, Ground. • Ensure proper termination (120 Ω at each bus end).
• Configure:
◦ Source Address (SA) ◦ PGNs used ◦ Baud rate (usually 250 kbps or 500 kbps)
Common PGNs for position sensors:
• PGN 61481 – Position/Angle Information • PGN 65103 – Proprietary A (if manufacturer-specific)
No microcontroller required.
Case B: Sensor with Generic CAN Output
You must create a translation layer.
Requirements:
• A microcontroller or CAN gateway
Examples:
◦ STM32 with FDCAN ◦ Arduino with MCP2515 + CAN transceiver ◦ ESP32 with CAN bus ◦ Commercial gateways (Kvaser DIN Rail, HMS Anybus)
Process:
1. Read sensor CAN frames. 2. Interpret angle data based on vendor data sheet. 3. Encode angle into appropriate J1939 PGN. 4. Send J1939 message onto the network.
Example J1939 angle SPN:
• SPN 1675 – Angular Position
Payload example (2 bytes): Angle = 0.0055° ⋅ raw
Case C: Sensor with SSI, SPI, Analog, PWM
You need to:
1. Interface with a microcontroller
• SSI → use timer + GPIO reading • SPI/I²C → direct MCU peripheral • Analog → ADC input• PWM → timer input capture
2. Convert measured angle to SPN scaling
3. Broadcast a J1939 PGN
A common PGN choice:
• PGN 61481 – Position (standard) • PGN 65280–65535 – Proprietary A/B PGNs (if no standard PGN fits)
3. Required J1939 Electrical Connections
Your sensor or interface must connect to the vehicle network:
CAN-H → CAN-H CAN-L → CAN-L +VBAT or +12/+24 V Ground (shared)
Ensure:
• Bus has two 120-ohm terminators at each end. • Stub length is short (typically < 1 meter). • Cable is twisted-pair, shielded preferred.
4. Encoding the J1939 Message
Typical J1939 encoder steps:
1. Choose PGN, for example: PGN = 61481 2. Set priority (usually 6) 3. Source address assigned dynamically or static 4. Pack angle data into 8-byte payloadExample payload structure:
• Byte 0–1: Angle (LSB, MSB) • Byte 2–7: Reserved (Ffh)
5. Example Microcontroller Pseudocode
|
|---|
raw = read_sensor()angle_deg = raw * resolution // from datasheetpayload[0] = (raw & 0xFF)payload[1] = (raw >> 8) & 0xFFpayload[2..7] = 0xFFsend_J1939(PGN_61481, priority=6, SA=my_address, data=payload)
|
|---|
6. Validation and Testing
Use:
• PCAN-View • Kvaser CanKing • Vector CANalyzer
There is obviously a lot of details t cover in implementing SAE J1939 protocol for a specific application that is beyond the scope of this newsletter article. Hopefully this overview will help with understanding the process, planning and some implementation. |
|---|
| | | |
| | | |