• First nuclear fusion power plant and its SPARC"core" • Sensor Tip: Understanding SAE J1939 interface and protocol • Application: Automated sod harvester • and more. |
|---|
To view newsletter in your browser click here.
|
|---|
|
Stock image representing a high temperature superconducting (HTS) fusion magnet |
|---|
WATCH VIDEO: Brief Animation of SPARC, a tokamak* to produce more energy output than input from nuclear fusion. |
|---|
*According to the U.S. Department of Energy, a tokamak is a machine that confines a plasma using magnetic fields in a donut shape that scientists call a torus. |
|---|
| | | |
| | | |
| | | |
SPARC Nuclear Fusion"Core" is Being Applied to the First Fusion Power Plant
| Stock image representing a fusion reactor |
|---|
WATCH VIDEO: Technology behind MIT's SPARC fusion reactor, made at a much smaller size than previously thought possible and made to be net energy producing. |
|---|
|
| In 2021 MIT created the SPARC fusion reactor. This was the first fusion reactor in the world to create sustained net energy output greater than the input — Q > 1. The project uses yttrium barium copper oxide (YBCO) high-temperature superconducting magnets, enabling magnetic fields up to 20 T at 20 K, a record for high-temperature superconducting magnets achieved in September 2021.1,4 It is much, much smaller than CERN’s Large Hadron Collider particle accelerator (~16.8 mi ring) with the same end goal.2 |
|---|
| | | |
| By November 2024, a prototype central solenoid was demonstrated, and the facility was largely completed. All of this work has now culminated in a detailed report by researchers at PSFC and MIT spinout company Commonwealth Fusion Systems (CFS), published in a collection of six peer-reviewed papers in a special edition of the March issue of IEEE Transactions on Applied Superconductivity. Then by January 2026, the first of 18 toroidal field magnets was completed and placed on an assembly jig called Tokamak at CFS’ Devens facility in Devens, Massachusetts.1,3 |
|---|
| Today the first fusion power station is being built in Virginia using SPARC technology. Commonwealth Fusion Systems has produced an up to date video of integrating the SPARC into their plant and when they plan on connecting the ARC power plant to the power grid with 400 MW of power. Their goal is to be the world’s first fusion powered plant in the early 2030s.5 |
|---|
|
| AI generated image representing a fusion power plant |
|---|
WATCH VIDEO: by Commonwealth Fusion Power about the first fusion power plant. |
|---|
| | | |
| | | |
|
History, Overview and How to Apply the SAE J1939 Interface
Origin of SAE J1939 and Why It Was Needed
SAE J1939 adds a 2nd software layer on top of the CANopen interface and protocol. This article covers this interface protocol in four sections: History of SAE J1939, an overview of the protocol, how to apply the protocol to an application in general, and how to connect a multi-turn sensor to a SAE J1939 protocol network. SAE J1939 did not appear suddenly. It evolved from earlier heavy-duty communication needs as commercial on-road and off-highway vehicles became more electronically controlled. Here’s a concise explanation of where it came from and why industry created it.
Historical Background
SAE created J1939 in the mid-1990s as a complete network protocol for heavy-duty and off-road vehicles, based on: • CAN 2.0B extended frame format (29-bit identifiers) • Concepts from earlier SAE standards like J1708/J1587, which J1939 replaced • J1939 was designed specifically to handle: • Harsh environments • Large multi-node networks • High reliability requirements • Interoperability between ECUs from different manufacturers |
|---|
SAE J1939 Developed by SAE (Society of Automotive Engineers)
Why J1939 Was Needed
1. Standardization Across Manufacturers
Before J1939, every OEM used different protocols. ECUs from one supplier could not easily talk to others. J1939 created:
• Unified PGNs (message types) • Standardized SPNs (parameters like engine speed, temperature,nangle and position) • Consistent diagnostics
This ensured interoperability across engines, transmissions, brakes, and auxiliary systems.
2. Reduction of Wiring Complexity
Older systems used point-to-point wiring:
• Hundreds of wires • Heavy, expensive harnesses • Difficult maintenance J1939 allowed multiple ECUs to share a single twisted-pair CAN bus, reducing wiring dramatically.
3. Heavy-Duty Requirements Exceeded Light-Duty Standards
ISO-9141, OBD-I/II, and early CAN implementations were too limited. J1939 provides:
• 29-bit extended identifiers for rich message encoding • Broadcast messaging • Large message support (Transport Protocol for multi-packet messages) • Flexible address handling (address claiming) • More robustness • Standardized parameter definitions • Larger networks across multiple ECUs from different vendors • Strong diagnostic capability These matched the complexity of heavy-duty vehicles.
4. Strong Diagnostic Capabilities
Maintenance is critical in commercial fleets. J1939 added:
• DM1 active fault messages • DM2 historical faults • SPN/FMI trouble codes • Standardized diagnostic tools
This allowed fleet operators and service centers to use common equipment.
5. Foundation for Industry-Specific Standards
J1939 became the base architecture for:
• ISO 11783 (ISOBUS) in agriculture • NMEA 2000 in marine systems • J1939-based industrial machinery protocols
Overview of the SAE J1939 Protocol
SAE J1939 is a high-level communications protocol widely used in heavy-duty vehicles such as trucks, buses, agricultural machinery, construction equipment, and marine engines. It defines how Electronic Control Units (ECUs) communicate over a CAN (Controller Area Network) bus to exchange diagnostic, control, and sensor information.
Key Characteristics
1. Based on CAN Bus
J1939 uses:
• CAN 2.0B (29-bit extended identifier) • 250 kbps or 500 kbps data rate depending on industry sector
The 29-bit identifier is central to J1939, defining message priority, function, and destination.
Identifier Structure (29-bit CAN ID)
J1939 messages use a structured identifier to encode information. The fields are:
• Priority (3 bits) • Reserved (1 bit) • Data Page (1 bit) • PDU Format – PF (8 bits) • PDU Specific – PS (8 bits) • Source Address – SA (8 bits)
The Parameter Group Number (PGN) is derived from part of this identifier and determines what data the message carries.
Parameter Group Number (PGN)
A PGN identifies a class of messages. Examples:
• PGN 61444 – Engine Speed and Torque • PGN 65262 – Engine Temperature • PGN 65365 – Diagnostic Messages
Each PGN contains one or more SPNs (Suspect Parameter Numbers), which represent individual measured values.
SPN (Suspect Parameter Number)
SPNs describe specific parameters inside a PGN:
• SPN 190 – Engine Speed • SPN 92 – Engine Percent Load • SPN 110 – Engine Coolant Temperature
Each SPN has defined scaling, units, and resolution.
Transport Protocol
Some data sets exceed CAN's 8-byte limit. J1939 supports:
• BAM (Broadcast Announce Message) – multi-packet broadcast • RTS/CTS (Request To Send / Clear To Send) – peer-to-peer flow-controlled transfer
This allows messages up to 1785 bytes.
Network Management
J1939 defines several management functions:
• Address Claiming – ECUs announce their address; allows dynamic assignment • Diagnostics – DTCs (Diagnostic Trouble Codes) using DM1, DM2, DM3 messages • Heartbeat – Periodic broadcasts confirming ECU presence
Typical Applications
J1939 is used in:
• Engine control • Transmission control • Braking systems (ABS/ESC) • Body controllers • Telematics and fleet monitoring • Agriculture (ISO 11783 is based on J1939) • Marine communication (NMEA 2000)
Benefits
• Standardized messages improve interoperability • Robust communication suitable for harsh environments • Scalable network with many ECUs • Strong diagnostic capabilities
Use the following link to read the rest of this newsletter article online for information on how to apply SAE J1939, electrical connections and how to connect a magnetic multi-turn sensor to a SAE J1939 protocol network: LEARN MORE. |
|---|
| | | |
| RSB 3600 Series single-turn sensor xxxxxxx |
|---|
|
The harvester shown is an automated combine for turf that drives and steers itself while an operator watches and performs quality control actions when needed. The harvesting process combines a number of automated control processes. The operator sets certain performance controls, turns on the turf cutter and pushes the drive control stick forward. After that the machine takes over and moves with hydrostatic drive.
Once in motion, turf is removed from the ground by the cutter-head blade cutting the turf in two places. An encoder measures the distance between cut points as the harvester rolls along the field of turf. Metal fingers pull the cut turf off the ground while it is cut along the sides and move it to a conveyor. Next the cut turf piece is moved along a conveyor belt up to rollers that roll the turf piece into a roll like a carpet.
A Novotechnik RSB 3600 absolute position sensor was selected as robust, reliable and with good accuracy for the application. On the harvester, the sensor measures movement covering 0 to 220 degrees of articulation. The robustness of this sensor is highlighted with its specifications of operating temperature range of -22 °F to + 185°F, shock and vibration of 50 and 20 g respectively as well as sealed housing to IP67. Additionally, a pair of RSB 3600 position sensors track the horizontal position and rotational position of the harvester’s dual-head stacker within 1/4 inch. The stacker’s angular range is 90 degrees. Learn more about the RSB 3600 Series sensors here. |
|---|
| | | |
| | | |
| |
| Please email suggestions for technical subjects you would like to suggest for this newsletter to this link: Newsletter Editor |
|---|
| | | | |
| |
|